Submit search
Geocel Plastic Roof Cement, Series: Roof Patch, 10 oz Capacity, Cartridge Packing, 255 g/l VOC, <20.5 cSt Viscosity, 8 pH, Liquid, Black, 24.1 ft Linear Coverage, 14 min Tack Free Drying Time, 1 - 3 days Functional Cure, 100.4 deg F Flash Point, Composition: Asphalt, Medium Aliphatic Hydrocarbon Solvent, Bentonite, Amine Salt, 1.03 Specific Gravity
Premier Plastic Roof Cement, Series: PR350, Dry/Wet, 29 oz, Cartridge, 0.22 VOC, Paste, Black, Strong Petroleum Solvent Odor/Scent, 120 Deg F Flash Point, Composition: 1,2,4-Trimethylbenzene, Aromatic Petroleum Distillates, Petroleum Asphalt, Attapulgite, Calcium Carbonate, Cellulose Fiber, Silica, Quartz, Stoddard Solvent, Flammability Rating: 2, 1.14 Specific Gravity, Standards: OSHA Compliant, For Emergency Repairs During inclement Weather Conditions
Henry Roof Sealant, Series: 289, Brush GRADE, 11 oz Capacity, Cartridge, 50 % VOC, Liquid, White, 12-1/2 sq-ft/gal at 1/8 in Thick Coverage, 2 - 4 hr Drying Time, Slight Odor/Scent, >212 Deg F Flash Point, Media: Carbon Dioxide, Water, Water Fog, Dry Chemical and Chemical Foam, Composition: Acrylic Polymer Blend, Benzyl Butyl Phthalate, Calcium Carbonate, Silica, Quartz, Titanium Dioxide, Water, Flammability Rating: 1, 1.39 at 77 Deg F Specific Gravity, Application Method: Brush or Trowel, Water Base, For Commercial and Residential Applications
Fibered repair mastic, designed to patch roof surfaces. Use in wet or dry conditions to seal and stop leaks around flashings, skylights, vent pipes, chimneys and valleys. For the repair of cracks, seams, and holes in all roofing materials. Can be used below grade as a heavy duty foundation water-proofing and damp-proofing. Thick trowel grade. Covers approximately 12 sq ft per gallon when applied 1/8" thick.
Henry Roof Leak Repair Cement, Wet Patch, Series: HE208, 1 qt, Can Packing, 22 % VOC, Paste, Black, 12.5 sq-ft/gal Coverage, Strong Petroleum Solvent Odor/Scent, >105 deg F Flash Point, Flammability Rating: 2, 1.14 Specific Gravity, Application Method: Trowel or Putty Knife, ASTM D2822-82, Type I
Geocel Roof Polyurethane Adhesive, Series: 3300, Professional GRADE, 10.1 oz Capacity, Cartridge, 3 g/l VOC, <0.205 cm-sq/s Viscosity, 2 - 11.5 pH, Liquid, Limestone, 24.1 ft Linear Coverage, 3 hr Tack-Free Drying Time, 1 Day Functional Cure, >199.9 Deg F Flash Point, Media: Carbon Dioxide, Dry Chemical, Water and Fog, Composition: Calcium Oxide, Calcium Carbonate, Titanium Dioxide, Flammability Rating: 0, 1.51 Specific Gravity, -20 To 150 Deg F Application, Applicable Materials: Stone, Masonry, Ceramics, Wood, Steel, Aluminum, Asphalt, BUR, Concrete, Fiberglass, Vinyl and Many Other Common Building Substrates, Application Method: Caulking Gun, 45 Shore A Shore, 200 psi Tensile, Mixing Ratio: 4:1, -20 To 150 Deg F, Standards: Meets ASTM C920 Types , GRADE NS, Class 25, Use NT, A, M, G, and O, Meets Federal Specification TT-S-0230 C, Type II, Class A, ISO Registered, 881% Elongation, For Concrete And Clay Roofing Tile, Metal Roofing, Kynar Coated Metal And Composition Shingles
Geocel Roof Polyurethane Adhesive, Series: 3300, Professional GRADE, 10.1 oz Capacity, Cartridge, 3 g/l VOC, <0.205 cm-sq/s Viscosity, 2 - 11.5 pH, Liquid, Black, 24.1 ft Linear Coverage, 3 hr Tack-Free Drying Time, 1 Day Functional Cure, >199.9 Deg F Flash Point, Media: Carbon Dioxide, Dry Chemical, Water and Fog, Composition: Calcium Oxide, Calcium Carbonate, Titanium Dioxide, Flammability Rating: 0, 1.51 Specific Gravity, -20 To 150 Deg F Application, Applicable Materials: Stone, Masonry, Ceramics, Wood, Steel, Aluminum, Asphalt, BUR, Concrete, Fiberglass, Vinyl and Many Other Common Building Substrates, Application Method: Caulking Gun, 45 Shore A Shore, 200 psi Tensile, Mixing Ratio: 4:1, -20 To 150 Deg F, Standards: Meets ASTM C920 Types , GRADE NS, Class 25, Use NT, A, M, G, and O, Meets Federal Specification TT-S-0230 C, Type II, Class A, ISO Registered, 881% Elongation, For Concrete And Clay Roofing Tile, Metal Roofing, Kynar Coated Metal And Composition Shingles
Geocel Roof Polyurethane Adhesive, Series: 3300, Professional GRADE, 10.1 oz Capacity, Cartridge, 3 g/l VOC, <0.205 cm-sq/s Viscosity, 2 - 11.5 pH, Liquid, White, 24.1 ft Linear Coverage, 3 hr Tack-Free Drying Time, 1 Day Functional Cure, >199.9 Deg F Flash Point, Media: Carbon Dioxide, Dry Chemical, Water and Fog, Composition: Calcium Oxide, Calcium Carbonate, Titanium Dioxide, Flammability Rating: 0, 1.51 Specific Gravity, -20 To 150 Deg F Application, Applicable Materials: Stone, Masonry, Ceramics, Wood, Steel, Aluminum, Asphalt, BUR, Concrete, Fiberglass, Vinyl and Many Other Common Building Substrates, Application Method: Caulking Gun, 45 Shore A Shore, 200 psi Tensile, Mixing Ratio: 4:1, -20 To 150 Deg F, Standards: Meets ASTM C920 Types , GRADE NS, Class 25, Use NT, A, M, G, and O, Meets Federal Specification TT-S-0230 C, Type II, Class A, ISO Registered, 881% Elongation, For Concrete And Clay Roofing Tile, Metal Roofing, Kynar Coated Metal And Composition Shingles
Geocel Roof Polyurethane Adhesive, Series: 3300, Professional GRADE, 10.1 oz Capacity, Cartridge, 3 g/l VOC, <0.205 cm-sq/s Viscosity, 2 - 11.5 pH, Liquid, Gray, 24.1 ft Linear Coverage, 3 hr Tack-Free Drying Time, 1 Day Functional Cure, >199.9 Deg F Flash Point, Media: Carbon Dioxide, Dry Chemical, Water and Fog, Composition: Calcium Oxide, Calcium Carbonate, Titanium Dioxide, Flammability Rating: 0, 1.51 Specific Gravity, -20 To 150 Deg F Application, Applicable Materials: Stone, Masonry, Ceramics, Wood, Steel, Aluminum, Asphalt, BUR, Concrete, Fiberglass, Vinyl and Many Other Common Building Substrates, Application Method: Caulking Gun, 45 Shore A Shore, 200 psi Tensile, Mixing Ratio: 4:1, -20 To 150 Deg F, Standards: Meets ASTM C920 Types , GRADE NS, Class 25, Use NT, A, M, G, and O, Meets Federal Specification TT-S-0230 C, Type II, Class A, ISO Registered, 881% Elongation, For Concrete And Clay Roofing Tile, Metal Roofing, Kynar Coated Metal And Composition Shingles
Gardner-Gibson Leak Stopper Roof Patch, Rubberized, 29 Fl Oz, <250 g/l VOC, 270 cPs Viscosity, Liquid, Black, 8 sq-ft/gal Coverage, 4 - 8 hr Setting, 24 - 48 hr Functional Cure, Petroleum Hydrocarbon/Solvent Odor/Scent, 105 deg F Flash Point, 1.0989 Specific Gravity, 50 - 120 deg F Application, Application Method: Trowel, 450 deg F, OSHA HCS2012
Through the Roof! Roof Sealant, 10.5 oz Capacity, Cartridge, 380 g/l VOC, Liquid, Clear, 30 ft Linear Coverage, 30 Min Tack-Free Drying Time, 1 week Functional Cure, Solvent Odor/Scent, 48 Deg F Flash Point, Media: Dry Chemical, Carbon Dioxide, Water Spray, Alcohol-Resistant Foam, Composition: Toluene, Solvent Naphtha, Light Aliphatic, Flammability Rating: 3, 0.88 Specific Gravity, 0 - 120 Deg F Application, Applicable Materials: Metal, Plastic and Other Surfaces, Application Method: Caulking Gun, 33 Shore A Shore, -25 To 180 Deg F, Resists: Excellent UV, Water and Mildew, Standards: Meets FHA Requirements, UL Listed, For Galvanized Metal and Aluminum Flashing, PVC and ABS Vent Pipe, Skylights, Gutters, Downspouts, Ductwork and Vents, Chimneys, Brick, Block and Mortar, Glue Down Shingles and Front Edges of Flat Roof Tiles, Metal Rv Roofs, Rubber Roof Membranes, Roof Jacks, Cables and Air Conditioning Units
Geocel Tripolymer Sealant, Series: Roof PRO, Elastomeric, High Performance, 10.3 oz Capacity, Cartridge, 341 g/l VOC, <0.205 cm-sq/s Viscosity, Liquid, Crystal Clear, 24.8 ft Linear Coverage, 45 Min Tack-Free Drying Time, 4 Days Functional Cure, 109 Deg F Flash Point, Media: Carbon Dioxide, Dry Chemical and Foam, Composition: Xylene, Light Aromatic Hydrocarbons, Cumene, 1,2,3-Trimethylbenzene, 1,3,5-Trimethylbenzene, 1,2,4-Trimethylbenzene, Flammability Rating: 2, 0.92 Specific Gravity, 0 - 140 Deg F Application, Applicable Materials: Asphalt Shingles, Coated Steel (Kynar 500 Based Finishes), Concrete, Steel, Vinyl and Other Common Building Substrates, Application Method: Caulking Gun, 20 Shore A Shore, 500 psi Tensile, Mixing Ratio: 4:1, Resists: UV, Standards: ISO Registered, 1062% Elongation, For Roofing Applications With Minimal Surface Preparation
Henry Crystal Clear Sealant, All Purpose, Series: HE212, 10.1 oz Capacity, Cartridge Packing, 35 % VOC, Viscous Liquid, Clear, 15 ft Linear Coverage, 4 hr, 30 Min Tack Free Drying Time, Solvent Odor/Scent, 75 deg F Flash Point, Composition: Ethyl Benzene, Hydrocarbon Resin, Polymer, Silica, Amorphous, Mineral Oil, Xylene, Flammability Rating: 3
Geocel Brushable Sealant, Series: Pro Flex, Multi-Purpose, 1 qt Capacity, Can, 468 g/l VOC, <0.205 cm-sq/s Viscosity, Liquid, Crystal Clear, 100 sq-ft Smooth Surface, 25 sq-ft Porous Surface Coverage, 120 Min Tack-Free Drying Time, 4 Days Functional Cure, Hydrocarbon Odor/Scent, 109 Deg F Flash Point, Media: Carbon Dioxide, Dry Chemical and Foam, Composition: Xylene, Light Aromatic Hydrocarbons, Cumene, 1,2,3-Trimethylbenzene, 1,3,5-Trimethylbenzene, 1,2,4-Trimethylbenzene, Flammability Rating: 2, 0.92 Specific Gravity, Applicable Materials: Asphalt Shingles, Coated Steel (Kynar 500 Based Finishes), Concrete, Steel, Vinyl and Other Common Building Substrates, Application Method: Brush, 52 Shore A Shore, 675 psi Tensile, Standards: ISO Registered, 776% Elongation, For Many Construction, Roofing, Manufacturing, and Industrial Applications
Through the Roof! Roof Sealant, 1 qt Capacity, Container, <550 g/l VOC, Liquid, Clear, 3 sq-ft Coverage, 30 Min Tack-Free Drying Time, 1 week Functional Cure, Solvent Odor/Scent, 63 Deg F Flash Point, Media: Dry Chemical, Carbon Dioxide, Water Spray, Alcohol-Resistant Foam, Composition: Mineral Spirits, Toluene Solvent Naphtha, Light Aliphatic, Flammability Rating: 3, 0.84 Specific Gravity, 0 - 120 Deg F Application, Applicable Materials: Metal, Plastic and Other Surfaces, Application Method: Foam or Paint Brush, 33 Shore A Shore, -25 To 180 Deg F, Resists: Excellent UV, Water and Mildew, Standards: Meets FHA Requirements, UL Listed, For Galvanized Metal and Aluminum Flashing, PVC and ABS Vent Pipe, Skylights, Gutters, Downspouts, Ductwork and Vents, Chimneys, Brick, Block and Mortar, Glue Down Shingles and Front Edges of Flat Roof Tiles, Metal Rv Roofs, Rubber Roof Membranes, Roof Jacks, Cables and Air Conditioning Units
Geocel Brushable Coating, Series: Instant Roof Repair, 1 qt Capacity, Can Packing, 547 g/l VOC, <20.5 cSt Viscosity, Liquid, Clear, 15 - 20 sq-ft Coverage, 4 hr Tack Free Drying Time, 109.4 deg F Flash Point, Media: Carbon Dioxide, Dry Chemical and Foam, Flammability Rating: 2, 0.91 Specific Gravity, Application Method: Brush, Trowel, Putty Knife
Through the Roof! Roof Sealant, 1 qt Capacity, Container, <300 g/l VOC, 40400 Dynamic Viscosity, Liquid, Clear, 3 sq-ft Coverage, 30 Min Tack-Free Drying Time, 1 week Functional Cure, Solvent Odor/Scent, 58 Deg F Flash Point, Media: Dry Chemical, Carbon Dioxide, Water Spray, Alcohol-Resistant Foam, Composition: P-Chloro-a,a,a-Trifluorotoluene, Toluene, Solvent Naphtha, Light Aliphatic, Flammability Rating: 3, 0.98 Specific Gravity, 0 - 120 Deg F Application, Applicable Materials: Metal, Plastic and Other Surfaces, Application Method: Foam or Paint Brush, 33 Shore A Shore, -25 To 180 Deg F, Resists: Excellent UV, Water and Mildew, Standards: Meets FHA Requirements, UL Listed, For Galvanized Metal and Aluminum Flashing, PVC and ABS Vent Pipe, Skylights, Gutters, Downspouts, Ductwork and Vents, Chimneys, Brick, Block and Mortar, Glue Down Shingles and Front Edges of Flat Roof Tiles, Metal Rv Roofs, Rubber Roof Membranes, Roof Jacks, Cables and Air Conditioning Units
Henry Plastic Roof Cement, Series: RC015070, 5 gal, Pail Packing, 200 g/l VOC, Fluid, Black, 12.5 sq-ft/gal Coverage, Mild Petroleum Solvent Odor/Scent, 105 deg F Flash Point, Composition: Asphalt, Petroleum Hydrocarbon and Petroleum Solvent (Mineral Spirits), Flammability Rating: 2, 1.47 Specific Gravity, Resists: Water, For Shingles, Concrete
Henry Plastic Roof Cement, Series: RC015042, 1 gal, Can Packing, 200 g/l VOC, Fluid, Black, 12.5 sq-ft/gal Coverage, Mild Petroleum Solvent Odor/Scent, 105 deg F Flash Point, Composition: Asphalt, Petroleum Hydrocarbon and Petroleum Solvent (Mineral Spirits), Flammability Rating: 2, 1.47 Specific Gravity, Resists: Water, For Shingles, Concrete
Gardner-Gibson Plastic Roof Cement, Series: Wet-R-Dri, 10 oz, <250 g/l VOC, Liquid, Black, 12 sq-ft/gal Coverage, Petroleum Solvent Odor/Scent, >105 deg F Flash Point, Composition: Asphalt, Mineral Spirits, Cellulose, Bentonite, 1,2,4?Trimethylbenzene, Benzene, 1,3,5-Trimethyl, Surfactant, 1.046 Specific Gravity, 50 - 120 deg F Application
Premier Plastic Roof Cement, Series: PR300, 4.75 gal, Liquid, Black, 12-1/2 sq-ft/gal Applied 1/8 in Thickness Coverage, Strong Petroleum Solvent Odor/Scent, 105 Deg F Flash Point, Composition: Petroleum Asphalt, Attapulgite, Bentonite, Cellulose Fiber, Stoddard Solvent, Water, Flammability Rating: 2, 1.01 Specific Gravity, Resists: Water, Standards: OSHA Compliant, For Repairing Leaks on Metal Roofs, Shingles, Composition Roofing and Asphalt
Premier Plastic Roof Cement, Series: PR300, 0.9 gal, Liquid, Black, 12-1/2 sq-ft/gal Applied 1/8 in Thickness Coverage, Strong Petroleum Solvent Odor/Scent, 105 Deg F Flash Point, Composition: Petroleum Asphalt, Attapulgite, Bentonite, Cellulose Fiber, Stoddard Solvent, Water, Flammability Rating: 2, 1.01 Specific Gravity, Resists: Water, Standards: OSHA Compliant, For Repairing Leaks on Metal Roofs, Shingles, Composition Roofing and Asphalt
Roofers Choice Roof Cement, Series: RC016, Fibered, Dry/Wet, 4.75 gal, 200 g/l VOC, Fluid, Black, 12-1/2 sq-ft/gal Applied 1/8 in Thickness, 30 sq-ft Per 5 gal Pail on a 3-Course Application Coverage, Mild Petroleum Solvent Odor/Scent, 105 Deg F Flash Point, Composition: Asphalt, Petroleum Hydrocarbon, Petroleum Solvent (Mineral Spirits), Flammability Rating: 2, 1.47 Specific Gravity, Application Method: Trowel, Resists: Water, Standards: OSHA 174 Approved, For Repairs Leaks in Shingles, Concrete, Gutters, Around Chimneys and Eaves
Premier Plastic Roof Cement, Series: PR350, Dry/Wet, 4.75 gal, Cartridge, 0.22 VOC, Paste, Black, Strong Petroleum Solvent Odor/Scent, 120 Deg F Flash Point, Composition: 1,2,4-Trimethylbenzene, Aromatic Petroleum Distillates, Petroleum Asphalt, Attapulgite, Calcium Carbonate, Cellulose Fiber, Silica, Quartz, Stoddard Solvent, Flammability Rating: 2, 1.14 Specific Gravity, Resists: Weather, Standards: OSHA Compliant, For Emergency Repairs During inclement Weather Conditions
Gardner-Gibson Plastic Roof Cement, Series: Wet-R-Dri, 5 gal, <250 g/l VOC, Liquid, Black, 12 sq-ft/gal Coverage, Petroleum Solvent Odor/Scent, >105 deg F Flash Point, Composition: Asphalt, Mineral Spirits, Cellulose, Bentonite, 1,2,4?Trimethylbenzene, Benzene, 1,3,5-Trimethyl, Water, 1.046 Specific Gravity, 50 - 120 deg F Application, 450 deg F
Premier Cold Process Adhesive Cement, Series: PR400, 4.75 gal, 300 g/l VOC, Fluid, Black, 50 sq-ft/gal Coverage, Strong Petroleum Solvent Odor/Scent, 105 Deg F Flash Point, Composition: Petroleum Solvent, Asphalt, Flammability Rating: 2, 0.99 Specific Gravity, Standards: OSHA Compliant, For Bonding and Cementing Asphalt Coated Sheets To Properly Prepared Roof Surfaces
FlashMaster Cement, Series: HE505, 5 gal, Pail Packing, <30 % VOC, Fibrous Paste, Black, 12.5 sq-ft/gal Coverage, Strong Petroleum Solvent Odor/Scent, 120 deg F Flash Point, Flammability Rating: 2, 1.03 Specific Gravity, Application Method: Trowel or Putty Knife, ASTM D4586, Type I and Federal Specification SS-C-153C Type I, Class A
Henry Roof Leak Repair Cement, Wet Patch, Series: HE208, 3.5 gal, Can Packing, 22 % VOC, Paste, Black, 12.5 sq-ft/gal Coverage, Strong Petroleum Solvent Odor/Scent, >105 deg F Flash Point, Flammability Rating: 2, 1.14 Specific Gravity, Application Method: Trowel or Putty Knife, ASTM D2822-82, Type I
Premier Cold Process Adhesive Cement, Series: PR400, 1 gal, 300 g/l VOC, Fluid, Black, 50 sq-ft/gal Coverage, Strong Petroleum Solvent Odor/Scent, 105 Deg F Flash Point, Composition: Petroleum Solvent, Asphalt, Flammability Rating: 2, 0.99 Specific Gravity, Standards: OSHA Compliant, For Bonding and Cementing Asphalt Coated Sheets To Properly Prepared Roof Surfaces
Sta-Kool Acrylic Sealant Roof Patch, Elastomeric, Series: 390, 10.1 oz, <45 g/l VOC, 190000 cPs at 77 deg F Viscosity, 8 at 77 deg F pH, Liquid, White, 25 sq-ft/gal Coverage, 24 - 48 hr Functional Cure, Acrylic Paint Like Odor/Scent, >247 deg F Flash Point, 1.44 Specific Gravity, 65 deg F Application, Application Method: Stiff Bristled Paint Brush