Submit search
HomeLine Circuit Breaker, GFCI, 120/240 VAC, 15 A, 1 Phase, 100A Frame, Fixed Trip, 20.25 A Trip, 10 kA Interrupt, 1 Poles, 14 - 10 AWG Wire, Screw Terminal, Plug On Mounting, 3.13 in Overall Length, 1 in Overall Width, 2.98 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, For Overload and Short Circuit Protection
HomeLine Circuit Breaker, GFCI, 120/240 VAC, 20 A, 1 Phase, 100A Frame, Fixed Trip, 27 A Trip, 10 kA Interrupt, 1 Poles, 14 - 10 AWG Wire, Screw Terminal, Plug On Mounting, 3.13 in Overall Length, 1 in Overall Width, 2.98 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, For Overload and Short Circuit Protection
Cutler-Hammer Circuit Breaker, Ground Fault, Type GFTCB, 120/240 VAC, 15 A, 10 kAIC Interrupt, 1 Poles, 14 - 4 AWG Wire, Plug-On Mounting, 1 in Space
Cutler-Hammer Circuit Breaker, Ground Fault, Type GFTCB, 120/240 VAC, 20 A, 10 kAIC Interrupt, 1 Poles, 14 - 4 AWG Wire, Plug-On Mounting, 1 in Space
Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 4.5" height x 1.25" width x 3" depth, .479 lb.
MES Circuit Breaker, Type MP-T, GFCI, 120/240 VAC, 20 A, 10 kA Interrupt, 1 Poles, Plug In Mounting, ANSI Specified, CSA Certified, UL Listed, Insta-Wire Connection, For Protection against Severe Electrical Shock and Electrocution
Square D Circuit Breaker, Type QO, GFCI, 120/240 VAC, 30 A, 1 Phase, 100A Frame, Fixed Trip, 40.5 A Trip, 10 kA Interrupt, 1 Poles, 14 - 8 AWG Wire, Pressure Plate/Screw Clamp Terminal, Plug On Mounting, 3 in Overall Length, 3/4 in Overall Width, 2.91 in Overall Depth, CSA Certified, UL Listed, For QO Load Centers and NQOD Panelboards
MES Circuit Breaker, GFCI, Miniature, 120 VAC, 20 A, 1 Phase, 125A/QP Frame, Fixed Trip, 10 kA Interrupt, 1 Poles, 14 - 10 AWG Wire, Lug Terminal, Plug In Mounting, 2.88 in Overall Length, 1 in Overall Width, 2.38 in Overall Depth, CSA Certified, UL Listed, Panelboard Mount, Used with Siemens Load Centers
Square D Circuit Breaker, Type QO, GFCI, 120 VAC, 20 A, 1 Phase, 100A Frame, Fixed Trip, 27 A Trip, 10 kA Interrupt, 1 Poles, 14 - 8 AWG Wire, Pressure Plate/Screw Clamp Terminal, Plug On Mounting, 3 in Overall Length, 3/4 in Overall Width, 2.91 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, For QO Load Centers and NQOD Panelboards
Square D Circuit Breaker, Type QO, GFCI, Miniature, 120/240 VAC, 15 A, 1 Phase, 100A Frame, Fixed Trip, 20.25 A Trip, 10 kA Interrupt, 1 Poles, 14 - 8 AWG Wire, Pressure Plate/Screw Clamp Terminal, Plug On Mounting, 3 in Overall Length, 3/4 in Overall Width, 2.91 in Overall Depth, ANSI Specified, CSA Certified, UL Listed
Cutler-Hammer Circuit Breaker, Ground Fault, Type CH, 120/240 VAC, 15 A, 10 kAIC Interrupt, 1 Poles, 14 - 6 AWG Wire, Plug-On Mounting, 3/4 in Space
Cutler-Hammer Circuit Breaker, Ground Fault, Type CH, 120/240 VAC, 20 A, 10 kAIC Interrupt, 1 Poles, 14 - 6 AWG Wire, Plug-On Mounting, 3/4 in Space
HomeLine Circuit Breaker, GFCI, Standard, 120/240 VAC, 50 A, 1 Phase, 100A Frame, Fixed Trip, 67.5 A Trip, 10 kA Interrupt, 2 Poles, 12 - 4 AWG/14 - 6 AWG Wire, Screw Terminal, Plug On Mounting, 3.13 in Overall Length, 2 in Overall Width, 2.98 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, For Overload and Short Circuit Protection
MES Circuit Breaker, GFCI, Miniature, 120/240 VAC, 50 A, 1 Phase, 125A/QP Frame, Fixed Trip, 10 kA Interrupt, 2 Poles, 8 - 6 AWG Wire, Lug Terminal, Plug In Mounting, 2.88 in Overall Length, 2 in Overall Width, 2.38 in Overall Depth, CSA Certified, UL Listed, Panelboard Mount, Used with Siemens Load Centers
Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 3" height x 2.25" width x 4.5" depth, .858 lb.
GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375.